Exterior sealing with ISOTEC
Our approach:

The problem:Lateral moisture penetration
If the exterior sealing is damaged or even lacking, moisture penetrates the masonry through the area that is in direct contact with the ground. Posible damages may include staining, chipping of paint and plaster, mould infestation and even flooding in the basement.

Our 1st step: Preparation/Plastering
We expose and clean the masonry which needs to be sealed. The junction between the masonry and foundation ledge is rounded out with a concave moulding. We then apply our ISOTEC Sealing Plaster. The plaster ensures ideal adhesion and an even spreading of the following sealing layer.

Our 2nd step: Sealing
We add a textile insert to the first layer of the bitumen and plastic emulsion (ISOTEC-VAS). We then apply another layer of the ISOTEC-VAS sealing. This way we obtain a sealing layer of at least 4 mm in depth.

Our 3rd step: Insulation/Protection
After the ISOTEC-VAS has dried completely, we apply special thermal insulation panels. These panels protect the insulation from damage when the ground is filled back in. In addition, they considerably improve the thermal insulation coefficient and thereby the energy balance of the building.
Officially approved - scientifically confirmed
At ISOTEC we only apply systems that comply with the strictest regulations. The ISOTEC Exterior Sealing is executed in compliance with the regulations of the WTA (German scientific-technical consortium for the preservation of buildings and monuments). Our ISOTEC Exterior Sealing also complies with all requirements of the Material Testing Office of North Rhine-Westphalia.

Your benefits at a glance
Environmentally-friendly and solvent-free
Better health, more safety
Successful sanitation guaranteed - permanent protection
The pleasant indoor climate after sanitation permits healthy and comfortable living
Improvement of heat insulation
Increase in property value
Exterior Sealing: Our satisfied customers
Hauptbahnhof, Mainz | Damage: Lateral moisture penetration
The ISOTEC Group has successfully sealed more than 100.000 properties in Germany, Austria and Switzerland in the last 25 years.
Amongst others, the ISOTEC Group also renovated the central station of Mainz, which is one of the most important railway junctions of the western Frankfurt Rhine-Main area. In addition to the ISOTEC Horizontal Barrier, the ISOTEC External Sealing was applied to the masonry at four metres of depth. Those measures have resulted in dry walls and the conservation of a beautiful and historic building.
![[Translate to Englisch:] Sanierung des Mainzer Hauptbahnhofs durch ISOTEC Außenabdichtung [Translate to Englisch:] Sanierung des Mainzer Hauptbahnhofs durch ISOTEC Außenabdichtung](/fileadmin/_processed_/e/8/csm_Sanierung-Hauptbahnhof-Mainz-ISOTEC_9912bb2afb.jpg)
Download area external sealing
- Brochure external sealing PDF ǀ 379 KB